• Users Online: 123
  • Print this page
  • Email this page
CASE REPORT
Year : 2013  |  Volume : 2  |  Issue : 1  |  Page : 238-240

Tracheo-oesophageal fistula - A disastrous complication of endotracheal intubation!


1 Associate Professor of Anaesthesiology, Kasturba Medical College, Manipal, India
2 Professor of Anaesthesiology, Kasturba Medical College, Manipal, India
3 Postgraduate in Anaesthesiology, Kasturba Medical College, Manipal, India

Correspondence Address:
Anitha Shenoy
Professor of Anaesthesiology, Kasturba Medical College, Manipal
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

A 28-year old man required invasive mechanical ventilation in view of organophosphorus poisoning in a peripheral hospital. His trachea was extubated ten days later following which he presented with dysphagia, voice change, burping, fever and cough. He was referred to our hospital for further management. His barium swallow radiograph showed a large tracheo-oesophageal fistula. Therefore, he was scheduled for oesophageal transection and colonic transposition. Following induction of anaesthesia, despite easy laryngoscopy view (Cormack Lehane grade 1), the tracheal intubation was found to be difficult as the tube tended to pass through the fistula into the oesophagus repeatedly as confirmed by absence of capnogram trace. Attempts to bypass the fistula using a fibreoptic scope and even a double lumen tube also failed. Identification of oesophageal intubation would have been missed or possibly detected late in this case with disastrous consequences but for absence of capnogram. Finally, the tracheal tube was successfully negotiated beyond the fistula with the help of a gum elastic bougie directed anteriorly into the trachea and a good capnogram was obtained. The surgery was uneventful and the trachea was extubated 24 h later in the intensive care unit following which the patient developed stridor requiring permanent tracheostomy. This case report illustrates the novel use for gum elastic bougie during tracheal intubation. This also highlights the importance of repeated measurement of tracheal cuff pressure in patients especially those receiving long duration mechanical ventilation.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed197    
    Printed7    
    Emailed0    
    PDF Downloaded24    
    Comments [Add]    

Recommend this journal